Over the last 20 years, Prime Power has developed an extensive selection of AC/DC Power Supplies. Prime Power can then take these proven AC/DC Power Supplies and modify them for our customers custom product needs. Modifying existing products from this library of proven, field tested custom power supplies allows Prime Power to reduce product lead times and reduce the rick incurred by customers looking for a custom power supply.
Prime Power has developed many custom power supplies to meet the requirements of MIL-STD-704 for aircraft, and MIL-STD-1339 for ships. Prime Power’s power supplies meet the requirements for voltage surges and spikes, as well as meeting the requirements of hold up time, and harmonic distortion.
Refueler Application
- Refueler application
- 115 VAC, 400hz input
- Meets MIL-STD-704A input requirements
- Meets MIL-STD-461 EMI requirements
- Custom designed 19 rack mount system
- Power on and LED on for each output
- Qualified to MIL-STD-810 requirements for airborne system
Nuclear Submarine Application
- 115 VAC input per MIL-STD-1399
- 5 Isolated/ Regulated outputs
- Designed to Navmat guidelines for derating
- EMI filtering per MIL-STD-461
- Qualified to shipboard requirements of MIL-STD-810
- Custom output voltage monitoring system
Aircraft Carrier Application
- 100-260 VAC , single phase @ 60 Hz
- 700 watt single out
- MIL-STD-1399 compliant for input including 200 msec hold up time
- MIL-STD-461E conducted, radiated and conducted susceptibility compliant
- Operating temperature range -40C to 85C
- Shock meets MIL-STD-901D
- Vibration to MIL-STD-167-1 type 1
- Water tight enclosure
Ground Radar Application
- 115 VAC single phase input, 47 – 400 Hz
- Single output at 300 watts
- Power factor of .99 @ 115VAC, 60 Hz
- Over temperature shutdown 105c
- Operating temperature -40c to +70c
- Shock per MIL-S-901, High impact grade A type A class 1
- Vibration, Altitude, per MIL-STD-810-1
- MIL-STD-461C for conducted emissions radiated and susceptibility.
Commercial Aircraft Communications
- 96 VAC -122VAC, 360 Hz to 800Hz
- Single output @ 100 watts output power
- 200 msec hold up time
- Operating temperature from -40c to +80c
- Qualified to DO160E requirements section 16 and 17
- Lightning induced transients 400 volts, 400 amps operational
- DO160E environmental sections 4,5,6,7,8 and 9 fully qualified
- MTBF 80,000 flight hours per MIL-HDBK-217F airborne , inhibited cargo.
- I2C interface capability
Prime Power has developed many custom power supplies to meet the requirements of MIL-STD-1275 for ground vehicles. Prime Power’s power supplies meet the various voltage surge and spike requirements and durations of MIL-STD-1275.
ARMY Shelter CPP
- Command Post Platform
- 3- Phase 208 VAC input voltage
- 28 VDC output-4500 watts
- Built- in test capabilities
- COTS design approach
- Power factor corrected .99pf
- Qualified to MIL-STD-810 requirements for ground mobile systems
- Qualified to MIL-STD-461 EMI requirements
Enhanced Position Locating Reporting System (EPLRS)
- 90-260 VAC input or 28 VDC input per MIL-STD-1275
- Qualified to MIL-STD-461D
- Active inrush circuitry
- Over voltage and over current protection
- Qualified to MIL-STD-810 requirements
- For mobile ground vehicle
- 28VDC output at 200 watts
Radar System
- Input 115VAC @60 Hz
- Multiple output system
- Operating temperature range -46C to + 85C
- Environmental to MIL-STD-810, shock, vibration, salt/fog and fungus
- MIL-STD-461B for conducted emissions radiated and susceptibility.
- All outputs isolated from each other.
- Slim design for limited space requirements.
- MIL-D- sub connectors for easy and quick connections